Pressix CC 27 - Channel System    
    
  Channels MS 27/15, 27/25 and 27/37
                  
                  
                  
                  Permissible load with centrical load application
|  L [cm]  |  27/15/1,25 [N]  |  27/25/1,25 [N]  |  27/37/1,25 [N]  | 
|---|---|---|---|
| 20 | 896 | 2031 |  3576 | 
| 40 | 447 | 1015 |  1786 | 
| 60 | 297 | 675 |  1189 | 
| 80 | 170 | 505 |  890 | 
| 100 | 107 | 388 |  710  | 
| 120 | 73 | 274 |  590 | 
| 140 | 52 | 199 |  504 | 
| 160 | 38 | 150 |  413 | 
| 180 | 28 | 116 |  323 | 
| 200 | 21 | 91 |  259 | 
| 220 | 15 | 73 |  210 | 
| 240 | 11 | 59 |  173 | 
| 260 | 7 | 47 |  144 | 
| 280 | 4 | 38 |  121 | 
| 300 | 2 | 31 | 102 | 
The influence of the channel slots and the channels 
dead weight are taken into account in the values. 
Calculations according RAL-GZ 655-C.
σperm ≤ 185 N/mm2
f ≤ L/200
![]()